Welcome at the electronic HID lamp ballasts page of HYTRONIK
HYTRONIK HID ballasts, build-in types (IP43), with lead wires These HID ballast with lead wires are suitable for both CDM, CHM and HCI lamps.
They combine compact, high power factor and low THD (<10) with automatic self diagnose. They indicate failures and abnormal operations like ignition failure, overheat, lamp failure, EOL etc.
These HYTRONIK HID ballasts are available in 20, 35, 70 and 150 Watt, wire lenght 20 cm, other wire lenghts on demand.
Model:
HM0020, 20W, 220-240 Volt, 50/60 Hz, -20 ~ +55 C, 50.000 hours
HM0035, 35W, 220-240 Volt, 50/60 Hz, -20 ~ +55 C, 50,000 hours
HM0070, 70W, 220-240 Volt, 50/60 Hz, -20 ~ +50 C, 50,000 hours
HM0150, 150W, 220-240 Volt, 50/60 Hz, -25 ~ +50 C,50,000 hours
HYTRONIK HID ballasts, build-in types (IP20), with terminal blocks These HYTRONIK HID ballast with push-in terminals are suitable for both CDM-TM, CHM and HCI lamps.
They combine compact, high power factor and low THD (<10) with automatic self diagnose. They indicate failures and abnormal operations like ignition failure, overheat, lamp failure, EOL etc.
These HYTRONIK HID ballasts are available in 20, 35, 70 and 150 Watt.
Model:
HM1020, 20W, 220-240 Volt, 50/60 Hz, -20 ~ +55 C, 50.000 hours
HM1035, 35W, 220-240 Volt, 50/60 Hz, -20 ~ +55 C, 50,000 hours
HM1070, 70W, 220-240 Volt, 50/60 Hz, -20 ~ +45 C, 50,000 hours
HM1150, 150W, 220-240 Volt, 50/60 Hz, -25 ~ +50 C, 50,000 hours
General HYTRONIK HID ballast features:
Suitable for CDM-TM, CMH, and HCI.
Steady lamp performance by mains fluctuation and lamp tolerance.
Constant lamp power output and stable lamp color temperature.
Protection against empty load damage.
Protection against overheat damage.
Protection against lamp end of life (EOL) damage.
Protection against lamp voltage to high damage.
Protection against lamp voltage to low damage.
Automatic restart on removing of faulty obstacles and power reset.
Pulse interval ignition.
Over 90% constant lumen factor during economical lamp life.
The comprehensive energy saving of 35% saves airco energy.
High power factor (>0.95)
Low THD (<10)
Automatic self diagnose.
50,000 service hours at Tc max.
Failure & abnormal diagnose and indication:
The HYTRONIK HID ballasts are programmed with diagnosis on failure and abnormal operation. The HYTRONIK HID ballasts monitors the fixture and send error signals to a LED in the ballast. The signal is carried through an optical fiber to a Lens on the enclosure of the fixture.
The signal is displayed as a number of red flashes which indicates different errors. The error signals are indicated in 10 seconds intervals and 1 second between each flash.
Failure & abnormal function codes:
1 Flash: Perfect function, NO failure, Action: NO action needed.
2 Flashes: Over-heated, Ballast gets too hot, Action: Analyze reason.
3 Flashes: Lamp failure, Ignition timed out, Action: Analyze reason.
4 Flashes: Lamp failure, Lamp End of life, Action: Change lamp.
5 Flashes: Lamp failure, Lamp voltage is to low, Action: Change lamp.
6 Flashes: Lamp failure, Lamp voltage is to high, Action: Change lamp.
7 Flashes: Ballast failure, Ballast doesn't work, Action: Change ballast.
Apart from the error signals, the LED also displays a single steady signal when the fixture tries to ignite the lamp.
Approvals and standards:
The HYTRONIK HID ballasts are tested and approved according to EN61347-2-12, EN61347-1, EN55015, EN61547, EN61000-3-2 and EN61000-3-3.
Do you need more information about the HYTRONIK products, please, send us an

|
|
|
 |